The Basics of Permanent Magnet Motor Operations
COURSE# - 5 The Physics of Permament Magnets • the outmost outline of the magnetization curve is for a single cycle of a fully magnetized magnet • as the operating point of the magnetic circuit's permeance P line intersects with the demagnetization curve the magnet "weakens"
Get Price
Basics of 3
Jul 23, 20181903 1/2hp Wagner repulsion start induction motor – The beast! Its a Heavy old monster of a 1/2hp motor. but true to repulsion induction motor form it doesnt even dim the lights in the room when it starts up! it has a loud magnetic hum when it runs. and the centrifugal switch is pretty loud as it snaps in and out.
Get Price
Understanding Centrifugal Pump and Motor Torque
Oct 08, 2019The torque-speed curve is similar for all centrifugal pumps due to simple math: the pump torque varies as the square of its speed. However, when the pump is at rest—0% full load speed—the full load torque is never also 0%. Starting a rotating pump requires the motor to overcome the pump inertia and static friction.
Get Price
Motor Starter Protection
In order to properly select an overcurrent device for a motor starter, four areas require particular attention: 1. Withstand rating of the contactor. 2. Wire Damage, 3. Cross-over point of the fuse and relay curve, 4. Motor Damage. Please refer to the following graph. Contactor Withstand Rating
Get Price
DIFFERENCE BETWEEN RUN AND START CAPACITORS
Start capacitors (ratings of 70 microfarad or higher) have three voltage classifications: 125V, 250V, and 330V. Examples would be a 35 uF at 370V run capacitor and an 88–108 uF at 250V start capacitor. Start capacitors increase motor starting torque and allow a motor to be cycled on and off rapidly. Start capacitors are designed for momentary
Get Price
Industrial Drives and Applications
Unit 1 upto torque-speed curves DC MOTOR DRIVES: (a) Starting braking, transient analysis, single-phase fully controlled rectifier, control of dc separately excited motor, Single-phase half controlled rectifier control of dc separately excited motor. paper mill dries and textile mill drives.
Get Price
8 reasons pumps operate off their curves
Oct 31, 2015Checking motor rotation uncoupled is ideal, but this may not be practical, in which case a running shaft rotation check is sufficient. 2. Pump Speed Differences. Any speed difference in the actual pump speed will cause a variation with the published curve. Different motor slips may cause small differences but typically only in the 15 to 20 RPM
Get Price
Ball Mill Design/Power Calculation
Jun 19, 2015A motor with around 1400 Horse Power is calculated needed for the designed task. Now we much select a Ball Mill that will draw this power. The ball mill motor power requirement calculated above as 1400 HP is the power that must be applied at the mill drive in order to grind the tonnage of feed from one size distribution. The following shows how
Get Price
Handbook of Electric Machines
Dec 03, 2019In order to limit the starting current of the motor, star-delta starting can be used for grid fed induction machines. The induction machine is started in star connection and later switched to delta connection. This reduces the starting peak current to one third (see Figure 9). However, the starting torque is also reduced to one third.
Get Price
Pulp Paper Mill Data and Costs
Apr 01, 2020Fastmarkets RISI's Mill Intelligence and cost analysis service provides insight into mill operations, cost, profitability and competitive standing for 4,500 assets in the global forest products industry. Our data and analysis cover all major mills producing
Get Price
Application of AC Induction Motors with Variable Frequency
mill motor could be specified as 600 – 1200 RPM CT, 1200 – 1320 CHP. Overload Requirements: Some applications call for the VFD and motor system to supply torques greater than the motor FLT for short periods of time. This can occur during starting and/or during the normal process. Overloads are typically stated in percents within a time period.
Get Price
Motor Starting Calculation (MS Excel Spreadsheet)
Aug 10, 2021A motor starting case study for any given electrical network can be performed by reducing the network to a smaller equivalent network consisting of a source (generator/grid), the starting motor (largest motor), another large running motor, and a lumped load. This MS Excel-based spreadsheet is based on this concept and presents a small model of
Get Price
Torque Speed Characteristics of Induction Motor
FIGURE 1 Induction motor torque-speed characteristic curves.. Figure 2 showed the equivalent circuit for the stator. We can simplify our calculations by replacing it with a Thevenin's equivalent so that we do not have parallel branches in the equivalent circuit. Figure 3 shows a Thevenin's equivalent of the stator.
Get Price
ELECTRICAL DRIVES CONTROL
2.6.2 torque-slip curve for induction motor 38 2.6.3 electric braking in ac induction motor 38 2.7 three phase induction motor 41 2.7.1 constructional details 42 2.7.2 working principle of three phase induction motor 45 3 starting methods 47 3.1 introduction 47 3.1.1 prime purpose (or) necessity of a starter for motors 47
Get Price
Overheating Electric Motors: A Major Cause of Failure
Apr 01, 2003Fig. 1 shows the NEMA derating curve for percentage of unbalance. According to the derating curve, the higher the level of unbalance, the lower the acceptable level of steady state load. For example, if a 100 hp motor has an unbalance factor of 3 percent, the motor should be derated to 0.88 or 88 percent of capacity, 88 hp.
Get Price
Understanding Motor Duty Rating
Dec 12, 2011One of the comments on my Motor Starting Series was asking for something on duty cycles. Here it is. As a purchaser of a motor, you have responsibility to let the manufacturer know the anticipated duty of the motor. To assist in the communication of this information, the standard IEC 60034-1 (Rotating electrical machines) defines several duty
Get Price
(PDF) Methods for the control of large medium
T ypical induction motor torque–speed–current curve. under cold weather conditions, a kiln or mill may hav e higher torque on initial start to establish material movement, and a
Get Price
S
5.1 Ideal S-Curve Referencing Figure 5-1, we assume a perfect S-curve with no linear transition period, and also examine the rise portion from v o to v s (the set speed) where v o = 0 if we are starting from rest. The following observations can be made: 1. The area under the concave and convex portions of the S-curve is the same as the area under
Get Price
Information and Recommendations for the Engineer FE
allow the user to determine if the motor has enough starting torque to overcome friction, to accelerate the load to full running speed, and if it can handle the maximum overload expected. See Figure 9 for a typical speed-torque curve. Figure 9. Typical Motor Speed-Torque Curve There are many torques that can be obtained from a motor's speed
Get Price
Lesson Learned: Centrifugal Pump End of Curve Operation
Mar 03, 2019Typically a pump will only achieve this end-of-curve operation if the motor is sized big enough otherwise it will trip before it ever reaches it. Thanks to process engineering expert Mr.Phil
Get Price
Sizing Gen
Feb 01, 2000Reducing motor starting kVA can reduce the required size of the gen-set, reduce the voltage dip, and provide a softer start for the motor loads. When sizing gen-sets, you must first determine the acceptable level of motor torque required during starting, or the loads will accelerate slowly, or even fail to reach full speed:ultimately causing
Get Price
Synchronous Motor Troubleshooting
Mar 09, 2014Mar 7, 2014. #1. I am new to this site, looking for some help with one of our old Westinghouse Motor Starters. We have an 1200 HP Synchronous motor with brushes. We have been experiencing exciter problems quite often when we have to restart or after a disturbance within our mill. The current problem we are experiencing is the mill was offline
Get Price
ball mill torque curve
speed torque curve and inertia of the mill. ball mill drive motor choices - Artec Machine Systems ball mills, the starting torque restrictions of some of the newer mill drive configurations, and the, costs and operating characteristics for each factor of comparison, in the past has been the low speed synchronous motor driving through an open pinion and bull gear, to accelerate the inertia
Get Price
INDUCTION MOTORS:INDUCTION MOTOR TORQUE
INDUCTION MOTOR TORQUE-SPEED CHARACTERISTICS. Figure 6.12a illustrates a squirrel-cage rotor of an induction motor that is operating at no load (near synchronous speed).The magnetization current IM flowing in the motor's equivalent circuit (Fig. 6.7) creates the net magnetic field Bnet.Current IM and hence Bnet are propor- tional to E1.Since E1 remains constant with the changes in load, then
Get Price
Motor starting capacitor
Motor start and motor run capacitors Start capacitors. Motor start capacitors are used during the motor startup phase and are disconnected from the circuit once the rotor reaches a predetermined speed, which is usually about 75% of the maximum speed for that motor type. These capacitors usually have capacitance values of over 70 F.
Get Price
Electromechanical Dynamic Behaviour and Start
Figure 10 shows the angular speed curves during the start-up process. In general, the motor can drive the ball mill to start. When =3 s, the clutch reaches the synchronous process and working speeds at 2.5 and 2.9 s, respectively. When =4 s, the clutch reaches the synchronous and working speeds at 3.6 and 3.9 s, respectively.
Get Price
Multilin 469
Motor Start Supervision Motor Start Supervision consists of the following features: Time-Between-Starts, Start-per-Hour, Restart Time. These elements are intended to guard the motor against excessive starting duty, which is normally defined by the motor manufacturer in addition to the thermal damage curves. Mechanical Jam and Acceleration Time
Get Price
Motor OL Class Curve Calculation
May 02, 2020For a motor with a 1.0 Service Factor that pick-up point can be 115% of FLA, for motors with a 1.15SF it can be 125% and for Mill Duty motors with a 1.25 or 1.30SF it can be 140%. The other end of that curve is the 600% level, so either 5, 10, 20 or
Get Price
Using Thermal Limit Curves to Define Thermal Models of
Dec 20, 2011Fig. 1. Hot and Cold Limit Curves for a 400-Horsepower Motor, SF = 1.15 The initial motor temperature values are marked on each curve. The curves are presented in accordance with guidelines in IEEE Standard 620-1996, Guide for the Presentation of Thermal Limit Curves for Squirrel Cage Induction Machines [2].